Icom MR-1000RTM Fish Finder User Manual


 
34
11
SERVICE MAN MENU
SPD adjustment
qPush [MENU]/[ ], [Ú] and [
] several times to
display the “SERVICE MAN” menu.
wPush [Ú] until the SPD ADJ. section becomes
highlighted.
ePush [
Ω≈
] to enter the pulse rate (pulse numbers
per one nautical mile) of the speed sensor unit.
rPush [MENU]/[ ] to return to the normal screen.
RANGE selection
qPush [MENU]/[ ], [Ú] and [
] to display the
“SERVICE MAN” menu.
wPush [Ú] until the RANGE section becomes high-
lighted.
ePush [Ù Ú] to choose the selectable screen ranges
with [+]/[ ] or []/[ ] on the display.
rPush [
] to skip from the range selection, or push
[
] to cancel skipping.
tPush [MENU]/[ ] to return to the normal screen.
Selectable ranges:
1
8,
1
4,
1
2,
3
4, 1, 1.5, 2, 3, 4, 6, 8,
12, 16, 24, 32, 36, 48* (NM)
*48 NM range is available for the MR-1000TII only.
SERVICE MAN
SPD ADJ.
HDG ADJ. 0.0
˚
HV
SETUP MEMORY
24000 MONITOR
HEATER
5731.0H
TX TIME
30.0
OUTPUT
ENGLISH
VOLTAGE
MG
340
75
3.0
0.55
TIMING ADJ.
1/8 3/4 2 6
1/4 1 3 8
1/2 1.5 4 12
16
24
32
36
48
RANGE
*
1
4 NM range will be skipped.
MR-1000R2_T2.qxd 04.2.24 10:22 Page 34