SPECIFICATIONS
DD
General
•Minimum range : 25 m; 82 ft (when measurement range is
1
⁄8 NM)
•Maximum range : 36 NM (MR-1000RII; when measurement range is 36 NM)
48 NM (MR-1000TII; when measurement range is 48 NM)
•Measurement range :
1
⁄8,
1
⁄4,
1
⁄2,
3
⁄4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36,
48* (NM) *MR-1000TII only
•Preheat time :
90 sec.
•Connection length between display and scanner unit : 15 m; 49
7
⁄32 ft (MR-1000RII),
20 m; 65
5
⁄8 ft (MR-1000TII, optional for MR-1000RII),
30 m; 98
7
⁄16 (optional)
DD
Scanner unit
◆ EX-2714 (Radome)
•Type : 2 feet Slotted Waveguide Array, enclosed in a radome.
•Rotation speed (typical) : 24 rpm, 36 rpm, 48 rpm (typ.)
•Beam width (typical) : Horizontal beam 4˚ (typ.)
Vertical beam 22˚ (typ.)
•Side lobe (typical) : –18 dB
•Polarization : Horizontal
•Transmission frequency : 9410 MHz ±30 MHz P0N
•Peak output power : 4 kW
•Pulse width : 80 nS/2880 Hz, 80 nS/2160 Hz, 250 nS/2160 Hz,
350 nS/2160 Hz, 900 nS/720 Hz.
•Mixer and Local Oscillator : Microwave Integrated Circuit
•Transmitting Tube : Magnetron MAF1421B
•Modulator : FET switching
•Duplexer : Circulator
•Tuning system : Automatic/manual selectable
•Intermediate frequency : 60 MHz
•IF Band width : 10 MHz, 3 MHz
•Dimensions : 607 (Ø)×243 (H) mm; 23
29
⁄32 (Ø)×9
9
⁄16 (H) in
•Usable temperature range : –25˚C to +70˚C; –13˚F to 158˚F
•Relative Humidity : Less than 95% at 35˚C (+95˚F)
•Weight : Approx. 8 kg; 17
5
⁄8 lb (without cable)
◆ EX-2780 (Open array)
• Type : 120 cm Slotted Waveguide Array
• Rotation speed (typical) : 24 rpm, 36 rpm, 48 rpm (typ.)
• Beam width (typical) : Horizontal beam 2˚ (typ.)
Vertical beam 25˚ (typ.)
• Side lobe (typical) : –24 dB
• Polarization : Horizontal
• Transmission frequency : 9410 MHz
±30 MHz P0N
• Peak output power : 4 kW
• Pulse width : 80 nS/2880Hz, 80 nS/2160 Hz, 250 nS/2160 Hz,
350 nS/2160 Hz, 900 nS/720 Hz.
•Mixer and Local Oscillator : Microwave Integrated Circuit
•Transmitting Tube : Magnetron MAF1421B
• Modulator : FET switching
• Duplexer : Circulator
• Tuning system : Automatic/manual selectable
• Intermediate frequency : 60 MHz
• IF Band width : 10 MHz, 3 MHz
• Diameter of rotation/height : 1205/381 mm; 47
7
⁄16/15 in
•Usable temperature range : –25˚C to +70˚C; –13˚F to 158˚F
• Relative Humidity : Less than 95% at 35˚C (+95˚F)
• Weight : Approx. 17 kg; 37
15
⁄32 lb (without cable)
MR-1000R2_T2.qxd 04.2.24 10:22 Page 37