Oceanic 04.1071.07 Scuba Diving Equipment User Manual


 
36
PRO PLUS 3 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-5332-r01 (11/19/12)

Dive Computer (Air or Nitrox).
Digital Depth Gauge/Timer.

Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm.
No Deco limits closely follow PADI RDP.
Decompression in agreement with Buhlmann ZHL-16c and French MN90.
No Deco Deep Stops - Morroni, Bennett.
Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik.
Altitude - Buhlmann, IANTD, RDP (Cross).
Altitude corrections and O2 limits based on NOAA tables.

 Accuracy:
Depth ±1% of full scale
Timers 1 second per day

Dives #1 to 24 (0 if no dive made yet).
Resets to Dive #1, upon diving (after 24 hours with no dives).

Stores 24 most recent dives in memory for viewing.
After 24 dives, adds 25th dive in memory and deletes the older dive.

Operational from sea level to 14,000 feet (4,270 meters) elevation.
Measures ambient pressure every 30 minutes when inactive, upon activation, every 15 minutes while activated.
Does not measure ambient pressure when wet.
Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.

(1) 3 volt, type CR2, Lithium battery.
Shelf life Up to 5 years, dependent on battery manufacturer.
Replacement User, annual recommended.
Use Life 100 dive hours if (1) 1 hour dives per dive day to 300 hours if (3) 1 hour dives per day.

Warning - icon on solid at 2.75 volts, battery change recommended.
Alarm - icon on ashing at 2.50 volts, change the battery.

• Manual - push button (recommended), required prior to dive if Wet Activation is set OFF.
• Automatic - by immersion in water if Wet Activation is set ON.
• Cannot be manually activated deeper than 4 FT (1.2 M), if Wet Activation is set OFF.
• Cannot operate at elevations higher than 14,000 feet (4,270 meters).

Out of the water - between 20 °F and 140 °F (-6 and 60 °C).
In the water - between 28 °F and 95 °F (-2 and 35 °C).
 segments
• No Deco Normal zone 1 to 3
• No Deco Caution zone 4
• Decompression zone 5 (all)
 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal zone 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
Caution zone 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast zone (ashing) 5 (all) > 30 > 9 5 (all) > 60 > 18
SPECIFICATIONS