19
AMPHOS DC MANUAL
© 2002 Design, 2012 Doc. No. 12-5301-r01 (12/17/12)
SET NIBG ALARM, information includes (Fig. 43):
> Graphic ON (or OFF), flashing.
> Bar graph segments with N2 icon.
> Graphic NIBG.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, advance to Set DTR Alarm.
>> if SEt is saved, the bar graph segments flash (SEt goes solid).
• S (< 2 sec) will step up from 1 to 5 segments in 0:05 (5 min) increments one at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected.
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET DTR (DIVE TIME REMAINING or RESERVE TIME) ALARM, information includes (Fig. 44):
> Graphic ON (or OFF), flashing.
> Reserve Time (min) with min icon.
> Graphic DTR.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, advance to Set PO2 Alarm.
>> if SEt is saved, the Time digits flash (SEt goes solid).
• S (hold) will scroll upward from 5 to 20 (min) in 1 min increments at 4 per sec.
• S ( < 2 sec) will step up through the Set Points one at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected.
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET PO2 ALARM information includes (Fig. 45):
> Graphic ON (or OFF), flashing.
> PO2 value with PO2, MAX, and NX icons.
> Graphic PO2.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, revert to Set A.
>> if SEt is saved, the PO2 digits flash (SEt goes solid).
• S (< 2 sec) will step up from 1.20 to 1.60 (ATA) in .10 increments one at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected.
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET U GROUP (UTILITIES)
Selections >> Wet Activation > Units > Deep Stop > Safety Stop > Conservative Factor > Backlight Duration > Sampling Rate.
> A + S (2 sec), while viewing Set A, will access Set U (Fig. 46).
> A (< 2 sec) will then access Set Wet Activation.
SET WET ACTIVATION, information includes (Fig. 47):
> Graphic OFF (or ON) flashing.
> Graphics Activ WET.
• S (< 2 sec) will toggle between ON and OFF.
• A (< 2 sec) will save the setting and access Set Units.
• A + S (2 sec) will save the setting and revert to Set U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET UNITS, information includes (Fig. 48):
> FT (or M) icons flashing.
> Graphics UNIT.
• S (< 2 sec) will toggle between Imperial and Metric.
• A (< 2 sec) will save the setting and access Set Deep Stop.
• A + S (2 sec) will save the setting and revert to Set U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
Fig. 43 - SET NiBG ALARM
Fig. 44 - SET DTR ALARM
Fig. 45 - SET PO2 ALARM
Fig. 46 - SET U GROUP
Fig. 47 - SET WET
ACTIVATION
Fig. 48 - SET UNITS