![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/54/d547ee4f-e8fa-4f3a-b0d7-a5e7fcfac992/d547ee4f-e8fa-4f3a-b0d7-a5e7fcfac992-bgba.png)
5: Commands and Levels
command mode serial string
Enables user to enter a custom string at boot time to enter com-
mand mode.
command mode serial string <string>
Sets a string that can be entered at boot time to enter command
mode.
<string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
Within {} specify decimal milliseconds time delay.
command mode signon message <string>
Sets a sign-on message that is sent from the serial port when the
device boots and when the line is in command mode.
<string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time <milliseconds>
Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
Uses seven bits for data on the line.
Uses eight bits for data on the line.
Restores the default speed of 9600 bits per second.
Restores the default of eight data bits.
Restores the default of no flow control.
Restores the default interface type to this line.
Restores the default of no parity.
Restores the default protocol on the line.
Restores the default of one stop bit.
Restores the factory default threshold.
Restores the default xoff character on this line.
Restores the default xon character on this line.
Exits to the enable level
Uses hardware (RTS/CTS) flow control on the line.
Does not provide flow control on the line.
Uses software (xon/xoff characters) flow control on the line.
Sets the gap timer in milliseconds. If some data has been re-
ceived, it will
be forwarded after this time since the last character.
Sets the line interface to RS232.
interface rs485 full-duplex
Sets the line interface to RS485 in full-duplex mode.
interface rs485 half-duplex
Sets the line interface to RS485 in half-duplex mode.
Sets the line interface to USB-CDC-ACM mode.
Kills command mode session on the Line
Enters the line level.
<line> = number of the line (serial port) to be configured.
Sets the name for this line.
Restores the serial counters to the aggregate values.
Disables command mode for the current line.
no command mode signon message
Clears the signon message displayed at boot time and when en-
tering
Removes the gap timer, so forwarding depends on the line speed.
Removes the name of this line.
PremierWave EN Command Reference 186