Furuno FCR-21x9 Marine RADAR User Manual


 
FURUNO
FCR-21x9-BB, FCR-28x9 SERIES
SP - 3 E3607S01A-M
Scroll, Symbol select, One touch activation,
Electric chart information auto-update
One-touch restore One-touch restore of standard mode
5.3 User interface
Position fixing Navigation by position from external EPFS,
Dead reckoning by gyro/log,
Route planning Planning by rhumb line, Great circle, Route creation
Route monitoring Off-track display, Waypoint arrival alarm, Shallow depth alarm,
Route information indication
User chart User chart creation
MOB (Man Overboard) Position, etc. at time of man overboard are recorded and
MOB mark is displayed on the screen.
6 INTERFACE
6.1 Processor unit (EC-3000)
Serial I/O 8 ports (IEC61162-1/2: 2 ports, IEC61162-1: 6 ports)
Input ABK, ABM, ALR, BBM, BWC, BWR, CUR, DBT, DPT, DTM,
ETL, GBS, GGA, GLL, GNS, HDT, MTW, MWD, MWV, NRM,
NRX, POS, PRC, RMB, RMC, ROR, ROT, RPM, RSA, RSD,
RTE, THS,TLL, TRC, TTM, VBW, VDM, VDO, VDR, VHW, VLW,
VTG, WPL, XDR, XTE, ZDA
Output AAM, ABM, ACK, BBM, CRQ, DDC, EVE, HTC, OSD, RSD,
TLB, TLL,TTD, VBW, VDR, VSD, XTE,XTR
Digital input 1 channel: contact signal, 100 ohm max. or 24VDC input
Alarm output 6 channels: contact signal 0.5A/60V max.
Normal close: 4, Normal open: 2 fixed
DVI output 3 ports: DVI-I Ver1.1, picture data (1 port for VDR)
USB 4 ports (3 ports for control units)
LAN 3 ports: Ethernet 1000Base-T for network equipment, sensor
adapter and spare
6.2 Sensor adapter (option)
MC-3000S (serial) 8 ports: I/O, IEC61162-1/2: 4 ports, IEC61162-1: 4 ports
MC-3010A (analog) 3 ports: Input, -10 to +10V, 0 to 10V or 4 to 20mA
MC-3020D (digital-in) 8 ports: relay contact, logics set from program
MC-3030D (digital-out) 8 ports: relay contact, normal open and normal close available
6.3 Radar processor unit (RPU-013)
Heading signal Sync signal (20-100VDC or 20-135 VAC, 50/60/400/500 Hz) or
stepper signal (20-100 VDC), built-in interface (option) required,
AD-10 format
7 POWER SUPPLY
7.1 Monitor unit (MU-231) 100-230 VAC, 1.0-0.6 A, 1 phase, 50/60 Hz
7.2 Processor unit (EC-3000) 100-115/220-230 VAC: 1.5-0.7 A, 1 phase, 50/60 Hz
7.3 Sensor adapter 24 VDC: 1.4 A (for 11 units), Input to MC-3000S, the sources of
other sensor adapters are fed from MC-3000S
7.4 Radar processor unit (RPU-013)
FCR-2119-BB/2819
100-115 VAC: 2.6 A (3.0 A), 1 phase, 50/60 Hz
220-230 VAC: 1.6 A (1.7 A), 1 phase, 50/60 Hz