Furuno FR-2135S Marine RADAR User Manual


 
4-4
Setting method 1: by gyrocompass specifications
1) Gyrocompass type 2) Frequency
Gyrocompass
type
SW
1-4
SW
1-5
SW
1-6
JP1 Frequency SW
1-7
SW
1-8
Remarks
AC synchronous OFF OFF OFF #1,
#2, #3
50/60Hz OFF OFF AC synchronous
pulsating current
DC synchronous OFF OFF OFF #2,
#3, #4
400Hz ON OFF AC synchronous
pulsating current
DC step ON OFF OFF #4,
#5, #6
500Hz OFF ON AC synchronous
pulsating current
Full-wave
pulsating current
OFF ON OFF #4,
#5, #6
DC ON ON DC synchronous
DC step
Half-wave
pulsating current
ON ON OFF #4,
#5, #6
3) Rotor voltage
(between R1 & R2)
4) Stator voltage
(between S1 and S2)
Rotor voltage SW 2-1 JP3 Stator voltage SW 2-2 SW 2-3 JP2
20 V to 45 VAC ON #2 20 V to 45 VAC, or
20 V to 60 VDC
ON OFF #2
30 V to 70 VAC OFF #2
40 V to 90 VAC ON #1 20 V to 45 VAC, or
20 V to 60 VDC
OFF OFF #2
60 V to 135 VAC OFF #1
40 V to 90 VAC ON OFF #1
60 V to 135 VAC OFF OFF #1
5) Ratio 6) Supply voltage
Ratio SW1-1 SW 1-2 SW1-3 Supply voltage JP4 JP5
360x OFF OFF OFF 20 V to 45 VAC, or
20 V to 60 VDC
#2 #2
180x ON OFF OFF
90X OFF ON OFF 30 V to 135 VAC, or
40 V to 100 VDC
#1 #1
36X ON ON OFF
7) AD-10 format data
Tx interval
9) NMEA-0183
Version no.
8) NMEA-0183
Tx interval and Output sentence
Select data transmitting interval for ports 1 to 6 by jumper wires
JP6 and JP7.
Tx
interval
SW
2-5
Note: The Tx interval is available in 25 ms or 200 ms.
25 ms is for radar; 200 ms is for all other equipment.
1 s
ON
ON
200 ms
OFF
100 ms OFF
SW
2-6
ON
ON
OFF
OFF
Output
sentence
HDT
HDT
HDT
HDT+VHW
25 ms
Version no.
OFF1.5
SW3-1
2.0 ON
10) NMEA-0183
Baud rate
Baud rate
OFF4860bps
SW3-2
38400bps ON
11) NMEA-0183
Talker
Talker
OFFAG
SW3-3
HE ON