2.4 Power Supply Units
Power supply unit PSU-001 (for scanner unit)
Two cables run to the Power Supply Unit PSU-001, the power cable (DPYC-3.5)
from the Power Supply Unit PSU-004 and the signal cable (660V-MPYCY-16) from
the scanner unit.
Clamp here.
Vinyl tape
Armor
Vinyl sheath
50 mm
5 mm
ANTI-CORROSIVE
SHEATH
5 mm
Vinyl sheath
Armor
150 mm
Vinyl tape
Crimp-on lug
FV5.5-4
Clamp here.
Signal Cable 660V-MPYCY-16
.oNeroCotdetcennoCguLno-pmirC
9ot12-BTP)deR(3M-52.1VF
61ot011-BTP)eulB(4-2VF
Power Cable 250V-DPYC-3.5
Core
S = 3.5
2
mm
φ = 2.4 mm
Armor
Vinyl sheath
(SECTIONAL VIEW)
300 mm
Figure 2-15 Fabrication and connection of power cable and signal cable
Cable clamp
PTB-2
PTB-1
Tap selection of T804:
connection of two
yellow wires should be
selected according to
supply voltage.
100VAC---tap"1"
110VAC---tap"5"
115VAC---tap"6"
Frequency setting of
HM801: Select the slide
switch position "60Hz" or
"50Hz". The slide switch is
located rear side of the
hour meter.
Hour Meter Slide view
Slide Switch
Rear
Front
Figure 2-16 Power supply unit PSU-001