Furuno FR-2165DS Marine RADAR User Manual


 
3-6
3.8 Initial Setting Menus
The INITIAL SETTING menus (four menus) and the OWN SHIP INFORMATION
menu setup the radar according to expected usage, authorities specification, ship's
characteristics, operator's preference, etc. Set items on each menu in accor-
dance with regulations/operator's preference. After entering initial settings, reset
the power.
[INITIAL SETTING 1]
1 [FUNCTIONS(4)]
2 HL ALIGN
EBL 0.0°
3 TIMING ADJ
VRM 00.00
4 ANT HGT 5m/7m/10m/15m/
20m/30mMORE
5 LOG PULSE 200P
6 [OWN SHIP INFORMATION]
7 MBS MBS TIMING VRM 0
MBS LEVEL EBL 0
8 ON TIME 000000.0H
9 TX TIME 000000.0H
0 [INITIAL SETTING(2)]
[INITIAL SETTING 2]
1 [INITIAL SETTING(1)]
2 LOG GYRO INPUT LOG
PULSE/SERIAL DATA
GYRO
AD/10/SERIAL DATA
3 OWN SHIP VECTOR COMPASS/COURSE
4 KEY BEEP ON/OFF
5 SCANNER STOPPED ST-BY/TX
6 VIDEO SIG ANALOG/DIGITAL
7 ALARM LEVEL 4/5/6/7
8 DISPLAY MAIN/SUB
9 SECTOR BLKG OFF/ON
000° → 000°
000° → 000°
0 [INITIAL SETTING(3)]
[INITIAL SETTING 3]
1 [INITIAL SETTING(2)]
2 TRAILS RESTART OFF/ON
3 ECHO AVG W/O GYRO OFF/ON
4 HEAD UP TB SCALE DEG/16POINT
5 CTR ECHO STRETCH OFF/ON
6 VIDEO CONTRAST 1/2/3
7 MAXIMUM RANGE 72/96/120
8 ECHO FULL COLOR OFF/ON
9 INDEX LINES 2/3/6
0 [INITIAL SETTING(4)]
[INITIAL SETTING 4]
1 [INITIAL SETTING(3)]
2 MODEL FR-2115, 2125/
OTHER X-BND/
FR-2165DS, 2135SW/
OTHER S-BND
3 TYPE R/N/G/D
4 CTR STC CURVE L/M/H
5 RJ-7 OFF/ON
6 RJ-8 OFF/ON
ANT A
FR-2115, 2125/
OTHER X-BND/
FR-2165DS, 2135SW/
OTHER S-BND
ANT B
FR-2115, 2125/
OTHER X-BND/
FR-2165DS, 2135SW/
OTHER S-BND
7 SHIP’S TYPE DEEP SEA/FISHING/
LONG LINE FISHING
8 RANGE UNIT NM/SM/Km
9 CABLE LENGTH 500m/5000m
0 FACTORY DEFAULT
[OWN SHIP INFORMATION]
1 [INITIAL SETTING(1)]
2 SHIP’S LENGTH 000m
3 SHIP’S WIDTH 00m
4 RADAR POSN FOR BOW 000m
FOR PORT 00m
5 NAV ANT POSN FOR BOW 000m
FOR PORT 00m
6 TURN RATE 00KT
00.0° / s
00KT
00.0° / s
7 SPEED RATE 00KT
0.00KT/s
00KT
0.00KT/s
Press [RADAR MENU] [0] [0] [0] [2]
Press [0]
Press [0]
Press [0]
Press [6]