Furuno FR-2165DS Marine RADAR User Manual


 
3-1
INITIALIZATION AND ADJUSTMENT
3.1 Tuning Initialization
Tune the radar as follows: Press [RADAR MENU] [0] [0] [2] [0] [0] [0] (TUNE
INITIALIZE on RADAR 3 menu) and press the [ENT] key. Also, confirm that
“2.MODEL” is set to “2165DS” in the INITIAL SETTING 4 menu, referring to page
3-6. If the setting is wrong, trouble may result.
3
.2 Accessing Menus for Initialization and Adjustment
To access them do the following:
1. Turn on the power.
2. Press the [RADAR MENU] key five times while pressing and holding down
the [HL OFF] key.
Restoring default settings
1. Press [RADAR MENU] [0] [0] [0] [2] [0] [0] [0] to display the INITIAL SETTING
4 menu.
2. Press the [0] key to select FACTORY DEFAULT.
3.3 Adjusting Video Signal Level
When the signal cable is very long, the video amplifier input level decreases,
shrinking target echoes. To prevent this, confirm (and adjust if necessary) video
amplifier input level.
1. Connect an oscilloscope to TP6 on the INT Board (03P9252) in the display
unit.
2. Transmit on the 12 nm range.
3. Adjust R21 on the INT Board so the value of TP6 is 4 Vpp. (For remote dis-
play, adjust R134 on the INT Board.)
TP6
R21
TP1
INT Board
(03P9252)
R134
Figure 3-1 Display pedestal