2
(2) Connection with the CNC (computerized numerical controller)
When one position detector is shared between FR-A7AP and
NC, its output signal should be connected as shown on the right.
In this case, the wiring length between FR-A7AP and NC should
be as short as possible, within 5m.
(3) Wire the shielded twisted pair cable after stripping its sheath to make
its cables loose.
Also, protect the shielded cable of the shielded twisted pair cable to
ensure that it will not make contact with the conductive area.
Strip off the sheath for the below length. If the length of the sheath peeled is too long, a short circuit
may occur with neighboring wires. If the length is too short, wires might come off.
Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not solder it
Use a blade terminal as necessary.
Maximum 5m
(two parallel cables)
CNC
Inverter
(FR-A7AP)
Position detecto
r
Encoder
Sheath
Shield
(perform protective treatment)
Twisted pair
shielded cable
(0.2 inches)5mm