6.3 2 kW radar processor connections
There are four interface connectors on the rear of the 2 kW radar processor, plus a Chassis Earth.
You can connect the Navico radar processor to either ot the following but not to any
simultaneously.
Simrad NX40 NX45, GB40
Northstar 8000i, 6100, 6000i, M84, M121
Lowrance GlobalMap 9300c HD, 9200c, 8300c, 8200c, Baja 440c, 7300c, 7200c, 5200c, 5300c,
Baja 540c, LCX-113c HD, LCX-112c, LCX-38c HD, LCX-37c, LCX-28c HD, LCX-27c, LMS-520c,
LMS-522c iGPS, LMS-525c DF, LMS-527c DF iGPS, X510c, X515c DF
2 kW radar processor interface connectors
Connector name Connector function Connects to...
Network Ethernet communications for
Simrad GB40 and Northstar
8000i
GB40 / 8000i network, using Navico
network cables (NS00481X). 0.5 m, 2
m, 5 m and 10 m available
Power (+ve and -ve) Power input Ship's power 12 V DC ONLY (using the
power cable)
NMEA / Comms Data communications for:
Simrad NX40/45
Northstar 6000i, 6100i, M84
and M121 systems)
Lowrance systems as above
Remote power control, relay
and ignition
NMEA communications for
compass input
Simrad NX40/45, Northstar 84/121
use the communication cable in the
radar connection kit (AA002461)
6000i or 6100i display unit, using
radar communications cable
(NS003107)
Lowrance systems as above using the
RIM300 Cable
6000i, 6100i, M84, M121 or 8000i
remote power signals, relay or
ignition; cable not supplied
NMEA / SimNet compliant compass;
cable not supplied
Scanner Scanner communications Scanner, using the interconnection
cable (NS003100 or NS003101)
Chassis earth Grounding point Vessel's Ground using ground wire