Simrad MN000802A-G Marine RADAR User Manual


 
12.7 Confirm the equipment installed
1. Confirm the type of navigator used with the radar (6000i, etc).
MAKE
MODEL
SERIAL NUMBER
SOFTWARE VERSION
2. Confirm that the NMEA Port 2 interface option is set to RADAR.
3. Confirm the type of radar installed:
2 kW dome
4 kW dome
6 kW open array
10 kW open array
25 kW open array
4. Make sure the voltage input and radar processor are correct for the system being installed, as
follows:
2 kW - 12 V DC - Radar Processor NS004780
4 kW - 12 V DC or 24 V DC - Radar Processor NS004781
6 kW - 12 V DC or 24 V DC - Radar Processor NS004782
10 kW - 24 V DC - Radar Processor NS004783
25 kW - 24 V DC - Radar Processor NS004784.
12.8 Are range rings displayed?
Yes, range rings are displayed.
1 Confirm that the installation set up had been performed.
2 Verify that the array is turning. If it is a dome, with the power off, remove the dome cover
(weather permitting). Apply power to the system. After the warm-up countdown has
completed, and the transmit option is set to ON, verify that the array is turning.
3 If the antenna does not turn, skip to the section "If the scanner fails to turn".
No, range rings or range scale information are not displayed.
1 Verify that the serial data cable wiring is correct for the communications cable.