Notification Explanation
BETTER GAS AVAILABLE
On multi-gas dive when ascending, it is
safe to switch to next available gas for
optimum decompression profile
LOW BATTERY
Approximately three hours of dive
time left
RE-CHARGE NEEDED
Approximately two hours of battery
time left; re-charging required before
next dive
SETPOINT SWITCHED
Setpoint switched automatically on
rebreather dive. See
3.23.3 Setpoints
TANK POD LOW
BATTERY
Tank POD battery life low; battery
change required
3.2.1 Configurable alarms
There are four configurable alarms: depth, dive time, tank pressure,
and gas time alarm. These alarm settings can be found under
Diving
settings
/
Alarms
. Each of these alarms can have its own limit and
be separately turned on or off.
NOTE: Tank pressure reading turns red if it goes below 50 bar
(720 psi).