Suunto SS020305000 Scuba Diving Equipment User Manual


 
Setpoint switching
Setpoints can be switched automatically according to depth. By
default the low setpoint switch depth is 4.5 m (15 ft), and the high
setpoint switch depth is 21 m (70 ft).
The auto setpoint switching is off by default for the low setpoint
and on for the high setpoint.
To change auto setpoint switching in Suunto EON Steel :
1. While in surface state, keep middle button pressed to enter main
menu.
2.
Scroll to Setpoint with the upper button and select with the
middle button.
3.
Scroll to Switch low or Switch high and select with the middle
button.
4. Adjust the depth value for the setpoint switch with the lower or
upper button and accept with the middle button.
5. Keep middle button pressed to exit menu.
Popup notifications indicate when the setpoint is switched.
During a rebreather dive, you can also switch to a custom setpoint
at any time.
55