Displaying arbitrary numbers on the 7SLED:
sys7SLED, out7SLED
The following commands are valid for the CARTESIAN Series only.
The following explains how to display arbitrary numbers on the 7SLED on the front body using
“out7SLED” command.
When executing “sys7SLED” command or switching programs, the program number will be
displayed again.
Command Category
Command Parameter
Job
Display the previous program
number before changed by
“out7SLED” command.
sys7SLED -
LCD, 7SLED
out7SLED
Display Type
Display value
Outputs number to 7SLED.
Parameter display type of “out7SLED” can be selected from the following 4 items. Display value
can also be specified using variables or expressions.
Display Type Description
Num Displays a specified number on the 7 SLED.
Er Displays one after the other between “Er” and a specified number.
St Displays one after the other between “St” and a specified number.
Ur Displays one after the other between “Ur” and a specified number.
Example: out7SLED Num,10: Display numeric value “10.”
out7SLED Er,20: Display one after the other between “Er” and “20.”
out7SLED St,nMyNum: Display “St” and a value of the variable “nMyNum.”
Features II CARTESIAN Benchtop Robot
75