13
Installation and Set-Up (Continued)
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles box
sizes up to 620 mm [24.5 inch] maximum height.
If larger capacity is needed, the machine can be
adjusted to accommodate boxes up to 725 mm
[28.5 inch] high. Refer to "Special Set-Up
Procedure – Box and Machine Bed Height
Range".
Note – Adjusting machine to accommodate 725
mm [28.5 inch] high boxes also increases
minimum box size to 165 mm [6.5 inch].
ELECTRICAL CONNECTION AND CONTROLS
The electrical control box (with circuit breaker)
and "On/Off" switch are located on the lower left
side of the machine frame. See Figure 3-1. If
desired, for operator convenience, the "On/Off"
switch can be relocated to the right side of the
machine frame. A standard three conductor power
cord with plug is provided at the back of the
electrical control box for 115 Volt, 60 Hz.
electrical service. The receptacle providing this
service shall be properly grounded. Before the
power cord is plugged into 115 Volt, 60 Hz outlet
make sure that all packaging materials and tools
are removed from the machine. Do not plug
electrical cord into outlet until ready to run
machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5 mm diameter
[AWG 16 ], have a maximum length of 30.5 m
[100 ft], and must be properly grounded.
Note – Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems or
other electrical requirements compatible with
local practice.
INITIAL START-UP OF CASE SEALER
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes
• To reduce the risk associated with
hazardous voltage:
− Position electrical cord away from foot and/or
vehicle traffic
WARNING