15
Operation (Continued)
Emergency Stop Switch
The machine electrical supply can be turned off by
pressing the latching emergency stop switch. To
restart machine, rotate emergency stop switch
(releases switch latch) and then restart machine by
pressing "I" (On) button on side of machine frame.
Electrical "On/Off" Switch
The box drive belts are turned on and off ("Off"
button is red) with the electrical switch on the side of
the machine frame.
Tape Loading/Threading
See Section II, Operation Section.
Note – The case sealer has a circuit breaker
located in the electrical enclosure on the lower left
side of the machine frame. If circuit becomes
overloaded and circuit breaker trips, unplug the
machine electrical cord and determine cause of
overload. After two minutes, open the electrical
enclosure and reset the circuit breaker by lifting
the reset lever. Close the electrical enclosure, plug
machine electrical cord into outlet and restart
machine by pressing "I" (On) button.
Note – If lower tape drum is mounted in alternate
lower outboard position, remove taping head from
machine bed by pulling straight up, insert
threading needle in taping head and replace
taping head. Install tape roll on drum (adhesive on
tape leg up), thread tape under knurled roller on
outboard mount, then attach tape to threading
needle and pull tape through taping head with
threading needle.
Important – Before turning drive belts on, be sure
no tools or other objects are on the conveyor bed.
• To reduce the risk associated with muscle
strain:
− Use proper body mechanics when removing
or installing taping heads that are moderately
heavy or may be considered awkward to lift
WARNING