8 Technical Data
8.1 General Data INV
DC input current ............................< rated input current
DC fuse required ...........................gL 80 A with type 3.3 kVA 48 V
gL 63 A with type 3.3 kVA 60 V
gL 20 A with type 3.3 kVA 220 V
gL 80 A with type 1.5 kVA 24 V
gL 36 A with type 1.5 kVA 48 V
gL 32 A with type 1.5 kVA 60 V
gL 25 A with type 2.5 kVA 110 V
Manufacturing and type test ..........In acc. with DIN 60146 Part 1-1
Emitted interference in acc. with EN 50081-1
- Conducted interference ..............In acc. with EN 55022 Class "B"
- Emission......................................In acc. with EN 55022 Class "B"
Noise immunity in acc. with EN 50082-2
- Housing .......................................ESD test to EN 61000-4-2,
6 kV contact
HF field to EN 61000-4-3,
10 V/m (30 MHz – 1 GHz)
- Power cables...............................Burst test in acc. with
EN 61000-4-4, 2 kV
Surge test in acc. with
EN 61000-4-5,
2 kV asymmetrical
- Control cables .............................Burst test in acc. with
EN 61000-4-4, 2 kV
Surge test in acc. with
EN 61000-4-5,
2 kV asymmetrical
Functional extra-low voltage..........With safe isolation at U
O
60 V DC
to VDE 0100 Part 410 11.83
Section 4.3.2
Dynamic response......................... 3% with sudden load fluctuations
between 0%-100%-0% rated
output current
Overload behaviour .......................1.6 x rated current for 1 minute
1.3 x rated current for 10 minutes
Short-circuiting...............................Continued short-circuit-proof