AEG 8000012364 BAL Marine Battery User Manual


 
"UniVert 2" inverter
Page 37 of 42 8000012364 BAL, en
Type
E-number
G48 – 60 E230/6,5/2rfg-CFp1,5
3000000351
G24 E230/6,5/2rfg-CFp1,5
3000000602
Rated output capacity 1.5 kVA
with power factor 0.8
Power factor range 0 inductive to 0 capacitive
Rated output voltage
230 V ±0.5 static, ±3% dynamic at 100% load change
Output frequency
50 Hz ±0.05%
THD factor < 3%
Rated output current 6.5 A 6.5 A
DC rated input voltage 48 V -15% / 60 V +20% 24 V -15% +20%
DC rated current 29 A at 48 V / 23 A at 60 V 62 A at 24 V
Efficiency > 85% > 80%
DC input current ripple < 10% of DC rated current
Monitoring systems
DC undervoltage, switch-off Fault < 85% of 48 V (40.8 V),
without delay
Acknowledgement > 103% of 48 V
(49.4 V), 15 s delay
Fault < 85% of 24 V (20.4 V),
without delay
Acknowledgement > 103% of 24 V
(24.7 V), 15 s delay
DC overvoltage, switch-off Fault > 128% of 60 V (76.8 V),
without delay
Acknowledgement < 125% of 60 V
(75 V), 15 s delay
Fault > 128% of 24 V (30,7 V),
without delay
Acknowledgement < 125% of 24 V
(30 V), 15 s delay
AC undervoltage, switch-off Fault < 90% rated (207 V), 2.5 s delay
Acknowledgement by ON/OFF switch
Overtemperature, switch-off
Fault > 80 °C, acknowledgement < 70 °C, approx. 5 s delay