DRAFT COPY
Decompression
Violations
Warning!
If you fail to complete a DECO stop,
the display will flash DECO Violation,
Schedule Not Verified and Go
Down! Descend immediately to
the indicated depth! If you violate
a deco schedule and see these
warnings, the Cobalt can no longer
compute a proper deco schedule
and the displayed schedule may no
longer be valid. You should still
complete any displayed schedule
before surfacing and if possible
make additional safety stops.
If you surface from a dive with this
warning you are advised to stop
diving and to seek medical
attention.
If you see this warning
stop diving and seek
medical attention!
This warning will remain
in the dive screen if you
attempt to dive again.
If you see these warnings
flash back and forth,
descend immediately to the
indicated stop depth!
The DECO VIOLATION will display in the Pre-Dive and Dive screens
for 24 hours. If you ignore these warnings and dive again, the
Cobalt will continue to function and display all dive data, however
the decompression information may not be valid!