Compass Recalibration Procedure
Turn on the computer, go to Main Menu, Settings, Calibrate
Compass.
Step 1. Orient the Cobalt along an estimated North-South
direction. Press SELECT to
start calibration. Step 1 will
begin flashing. Rotate the
Cobalt in a North-South plane
until Step 1 stops flashing
and Step 2 begins to flash.
Step 2. Turn 90 degrees and
point the Cobalt East-West.
Rotate on its lengthwise axis
on the east-west plane, until
Step 2 stops flashing and the
compass appears.
Check the compass function
and repeat if needed. If
satisfied, select the Save
button.
Exit the calibration screen
using the BACK button.
Avoid exposing the Cobalt to strong magnetic fields. These can
alter the compass calibration. Note that diving near large metal
masses may alter the accuracy of any compass.