Black Box 1102 Marine Safety Devices User Manual


 
1101 and 1102 Secure Device Servers
724-746-5500 | blackbox.com
32
Figure 5-9. SDT settings.
For configuration details, refer to Chapter 6.4—Using SDT Connector to Telnet or SSH connect to devices that are serially attached to the console
server.
5.1.4 Device (RPC, UPS, EMD) Mode
This mode configures the selected serial port to communicate with a serial controlled Uninterruptable Power Supply (UPS), Remote Power
Controller/Power Distribution Unit (RPC) or Environmental Monitoring Device (EMD).
Figure 5-10. Device settings screen.
Select the desired Device Type (UPS, RPC or EMD)
Proceed to the appropriate device configuration page (Serial & Network: UPS Connections, RPC Connection or Environmental) as detailed in
Chapter 8—Power Management.
5.1.5 Terminal Server Mode
Select Terminal Server Mode and the Terminal Type (vt220, vt102, vt100, Linux, or ANSI) to enable a getty on the selected serial port.
Figure 5-11. Terminal server settings screen.
The getty will then configure the port and wait for a connection to be made. An active connection on a serial device is usually indicated by the Data
Carrier Detect (DCD) pin on the serial device being raised. When a connection is detected, the getty program issues a login: prompt, and then
invokes the login program to handle the actual system login.
NOTE: Selecting Terminal Server mode will disable Port Manager for that serial port, so data is no longer logged for alerts, etc.
5.1.6 Serial Bridging Mode
With serial bridging, the serial data on a nominated serial port on one console server is encapsulated into network packets and then transported
over a network to a second console server. It is then represented on its serial port again as serial data. The two console servers effectively act as a
virtual serial cable over an IP network.
One console server is configured as the Server. Set the Server serial port to be bridged in Console Server mode with either RFC2217 or RAW
enabled (as described in Chapter 5.1.2—Console Server Mode).
For the Client console server, the serial port to bridge must be set in Bridging Mode: