Furuno fsv85 SONAR User Manual


 
1. HOW TO INSTALL THE SYSTEM
1-16
1.8 FRP Tank (option)
OP10-29. Code No. 000-067-178
Use an FRP tank supplied by FURUNO. Other makes of tank may be used, however
watertightness cannot be guaranteed by FURUNO. A non-FURUNO make of tank
should meet the following requirements:
The surface of the FRP tank flange must be flush (within 0.5 mm) with tank.
Use the liquid gasket recommended by shipyard.
1.8.1 How to install the hull unit to an FRP tank
Fasten the hull unit to the FRP retraction tank as follows:
1. Clean the surface of the tank flange with ethyl alcohol moistened waste cloths.
Coat the flange with about 1mm thickness of liquid gasket (supplied). USE ONLY
THE SUPPLIED liquid gasket.
2. Lay the waterproofing gasket on the tank flange and coat the gasket with about 1
mm thickness of liquid gasket.
Note: Use only specified waterproofing gasket.
3. Position the bow mark (arrow) on the hull unit flange toward ship's bow. (If the
mark can not be perfectly oriented toward ship's bow, adjust heading after instal-
lation, as shown later in this manual.
Name Type Code No. Qty
Retraction Tank OP10-29-1 007-022-920 1
Waterproofing Gasket SHH-0003-1 660-800-031 1
Liquid Gasket TB1194 200G 000-164-260-10 1
Liquid gasket
2 mm
100 mm
FRP TANK
1 mm
Waterproofing gasket (1 mm)
FRP TANK
Liquid gasket
Flange
BOW
Bow mark