Graco E-FLO 4000 Marine Sanitation System User Manual


 
Repair
40 311594Z
j. Thread the IS field wire through the conductive
strain relief (74a). Connect the TDC wires to J2,
the transducer wires to J3, and the position sen-
sor wires to the two terminal blocks (46). See
F
IG
. 29 and the Electrical Diagrams, page 12.
k. See F
IG
. 30. Tighten the nut (N) on the conduc-
tive strain relief (74a) securely. Install the ferrite
(77) on the field wire (F), not more than 2 in. (51
mm) from the bottom of the conductive strain
relief (74a). Install the ground wire (G) to the
grounding screw in the junction box.
11. Install the new gasket (33), the cover (34), and six
screws (12).
12. Reinstall the covers (32 and 21) and screws (12).
13. Add 2 quarts of gear oil, Part No. 288414.
F
IG
. 30. IS Circuit Field Wire
ti16891b
F
N
77
B
74a
Not more than
2 in. (51 mm)
G