296
Setting from the parameter unit, operation panel
(1) Setting the frequency with the setting dial
Operation example
Operate at 30Hz.
Operation Display
1. Screen at power-ON
The monitor display appears.
2. Operation mode change
Press to choose the PU operation mode.
PU indicator is lit.
3. Frequency setting
Turn to show the frequency " " (30.00Hz) you want
to set. The frequency flickers for about 5s.
4. While the value is flickering, press to set the frequency.
(If is not pressed, the indication of the value goes back to
" " (0.00Hz) after about 5s of flickering. In that case, turn
again, and set the frequency.)
After about 3s of flickering, the indication of the value goes back to "
" (monitor display).
Flicker ··· Frequency setting complete!!
After 3s, the monitor display
appears.
5. Start → acceleration → constant speed
Press or to start operation.
The frequency value on the display increases in Pr. 7 Acceleration
time, and " " (30.00Hz) appears.
/
6. To change the set frequency, perform the operation in above step 3 and 4. (Starting from the previously set frequency.)
7. Deceleration → stop
Press to stop. The frequency value on the indication
decreases in Pr. 8 Deceleration time, and the motor stops rotating
with " "(0.00Hz) displayed.
REMARKS
⋅ If is not pressed within 5s after is turned, the operation may not performed at the set frequency.
PU EXT NET
Flickers for about 5s
Stop