66
Parameter list
Automatic
restart functions
57
Restart coasting time
0, 0.1 to 5s, 9999/
0, 0.1 to 30s, 9999
*2
0.1s 9999 162
58
Restart cushion time 0 to 60s 0.1s 1s 162
59
Remote function selection 0, 1, 2, 3, 11, 12, 13 1 0 106
60
Energy saving control selection 0, 4, 9 1 0 176
65
Retry selection 0 to 5 1 0 172
66
Stall prevention operation reduction
starting frequency
0 to 400Hz 0.01Hz 60Hz 91
Retry
67
Number of retries at fault occurrence 0 to 10, 101 to 110 1 0 172
68
Retry waiting time 0 to 10s 0.1s 1s 172
69
Retry count display erase 010172
70
Special regenerative brake duty 0 to 10% 0.1% 0% 125
71
Applied motor 0, 1, 2, 20, 120, 210 1 0 122
72
PWM frequency selection 0 to 15/0 to 6, 25 *2 12182
73
Analog input selection 0 to 7, 10 to 17 1 1 185
74
Input filter time constant 0 to 8 1 1 192
75
Reset selection/disconnected PU
detection/PU stop selection
0 to 3, 14 to 17 1 14 198
76
Fault code output selection 0, 1, 2 1 0 174
77
Parameter write selection 0, 1, 2 1 0 200
78
Reverse rotation prevention selection 0, 1, 2 1 0 201
79
Operation mode selection 0, 1, 2, 3, 4, 6, 7 1 0 206
Simple magnetic
flux vector control
IPM motor control
80
Motor capacity
0.4 to 55kW, 9999/
0 to 3600kW, 9999
*2
0.01/0.1kW 9999 89
90
Motor constant (R1)
0 to 50
Ω
, 9999/
0 to 400m
Ω
, 9999
*2
0.001Ω/
0.01mΩ
9999 89
Adjustable 5 points V/F
100
V/F1(first frequency) 0 to 400Hz, 9999 0.01Hz 9999 101
101
V/F1(first frequency voltage) 0 to 1000V 0.1V 0V 101
102
V/F2(second frequency) 0 to 400Hz, 9999 0.01Hz 9999 101
103
V/F2(second frequency voltage) 0 to 1000V 0.1V 0V 101
104
V/F3(third frequency) 0 to 400Hz, 9999 0.01Hz 9999 101
105
V/F3(third frequency voltage) 0 to 1000V 0.1V 0V 101
106
V/F4(fourth frequency) 0 to 400Hz, 9999 0.01Hz 9999 101
107
V/F4(fourth frequency voltage) 0 to 1000V 0.1V 0V 101
108
V/F5(fifth frequency) 0 to 400Hz, 9999 0.01Hz 9999 101
109
V/F5(fifth frequency voltage) 0 to 1000V 0.1V 0V 101
PU connector communication
117
PU communication station number 0 to 31 1 0 229
118
PU communication speed 48, 96, 192, 384 1 192 229
119
PU communication stop bit length 0, 1, 10, 11 1 1 229
120
PU communication parity check 0, 1, 2 1 2 229
121
Number of PU communication retries 0 to 10, 9999 1 1 229
122
PU communication check time
interval
0, 0.1 to 999.8s, 9999 0.1s 9999 229
123
PU communication waiting time
setting
0 to 150ms, 9999 1 9999 229
124
PU communication CR/LF selection 0, 1, 2 1 1 229
Function Parameters
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer