68
Parameter list
⎯
160
User group read selection 0, 1, 9999 1 9999 201
⎯
161
Frequency setting/key lock operation
selection
0, 1, 10, 11 1 0 295
Automatic restart
functions
162
Automatic restart after instantaneous
power failure selection
0, 1, 10, 11 1 0 162
163
First cushion time for restart 0 to 20s 0.1s 0s 162
164
First cushion voltage for restart 0 to 100% 0.1% 0% 162
165
Stall prevention operation level for
restart
0 to 150% 0.1% 120% 162
Current
detection
166
Output current detection signal
retention time
0 to 10s, 9999 0.1s 0.1s 146
167
Output current detection operation
selection
0, 1, 10, 11 1 0 146
⎯
168
Parameter for manufacturer setting.
Do not set.
⎯
169
Cumulative
monitor clear
170
Watt-hour meter clear 0, 10, 9999 1 9999 152
171
Operation hour meter clear 0, 9999 1 9999 152
User group
172
User group registered display/batch
clear
9999, (0 to 16) 1 0 201
173
User group registration 0 to 999, 9999 1 9999 201
174
User group clear 0 to 999, 9999 1 9999 201
Input terminal function assignment
178
STF terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 60, 62, 64 to 67,
70 to 72, 9999
160133
179
STR terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 61, 62, 64 to 67,
70 to 72, 9999
161133
180
RL terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 62, 64 to 67, 70
to 72, 9999
10133
181
RM terminal function selection 11133
182
RH terminal function selection 12133
183
RT terminal function selection 13133
184
AU terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 62 to 67, 70 to
72, 9999
14133
185
JOG terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 62, 64 to 67, 70
to 72, 9999
15133
186
CS terminal function selection 16133
187
MRS terminal function selection 124133
188
STOP terminal function selection 125133
189
RES terminal function selection 162133
Function Parameters
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting