2.3. Com pressed-air sup ply
For op er at ing the con trol valves and the clean ing unit, a com pressed-air sup ply is
nec es sary.
L
Depressurize com pressed-air sup ply lines which must be
opened.
F
Com pressed air must be dewatered, dustfree and oilfree.
In stall a main te nance unit if re quired.
Ad just pres sure to a max. value of 6 bar (87.02 PSI) (sys tem
overpressure).
Check com pressed-air pip ing for cor rect in stal la tion and as sem bly.
Check fit tings, length and qual ity of the hose con nec tions for agree ment with re -
quire ments.
The op er at ing pres sure is 5-6 bar (72.52-87.02 PSI) (sys tem overpressure).
Check the com pressed-air sup plied by the plant’s sup ply net work.
Ad just com pressed-air pres sure to 5-6 bar (72.52-87.02 PSI) (sys tem
overpressure).
Con nect the unit to the plant’s sup ply net work by means of a hose.
526-3MS
SSP 5