Sterling SSP 5 Marine Battery User Manual


 
5.3.1. Ad just the flap switch
Re move the con nect ing plug “flap switch” from the con nec tion hous ing of the
hop per.
Con nect an ohm me ter to PINS 2 and 3 of the con nect ing plug “flap switch”.
Re lease the nuts (A) of the flap switch (B) un til the sup port can be dis placed.
Open the out let flap (C) so far that
the front tip of the out let flap is
approx. 30 mm (1.28 in.) away from
the seal ing sur face.
Dis place the flap switch (B) un til
the con tact of the mag net switch is
closed.
Tighten the nuts (A) of the flap
switch.
Check the ad just ment:
In case of free hang ing out let flap
(empty hop per loader) the con tact
of the mag net switch must be
closed.
If the out let flap can not be prop erly ad justed, re place the flap switch or the out let
flap with mag net.
In stall the hop per.
&
Or der num bers
flap switch: ID 28839
out let flap with mag net: ID 23093
526-3MS
SSP 5
Main te nance 26
Out let flap
C B A