SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
2-5 Installing the System into a Rack
This section provides information on installing the 6016T-6RFT+/6016T-6RF+ into
a rack unit with the rack rails provided. If the system has already been mounted
into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack
units on the market, which may mean the assembly procedure will differ slightly.
You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner xed chassis rail that secures directly
to the server chassis and an outer xed rack rail that secures directly to the rack
itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of
the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis. Pro-
ceed to the next step.
Figure 2-1. Identifying the Sections of the Rack Rails
(left side rail shown)
Inner Rail Outer RailLocking Tab
Warning: do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.