2-6
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
Installing the Server into the Rack
Installing the Chassis into a Rack (Figure 2-3)
1. Con rm that chassis includes the inner rails and rail extensions . Also, con rm
that the outer rails are installed on the rack.
2. Line chassis rails with the front of the rack rails.
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs "click".
4. (Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.
Installing the Server into a Telco Rack
To install the 6016T-6RFT+/6016T-6RF+ into a Telco type rack, use two L-shaped
brackets on either side of the chassis (four total).
1. First, determine how far follow the server will extend out the front of the rack.
Larger chassis should be positioned to balance the weight between front and
back. If a bezel is included on your server, remove it.
2. Then attach the two front brackets to each side of the chassis, then the two
rear brackets positioned with just enough space to accommodate the width of
the telco rack.
3. Finish by sliding the chassis into the rack and tightening the brackets to the
rack.
Note: Figure is for illustrative purposes only. Always install servers to the bottom
of a rack rst.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.