Xantrex Technology TS400 Marine Battery User Manual


 
Installation
28 975-0055-01-01
Battery Requirements
The batteries that you use strongly affect the performance of the TS400. It
is important to connect the inverter to the correct size and type of battery.
See Appendix B, Battery Types and Sizes on page B1 for more
information.
Close to
battery
compartment
Long DC cables must be very large (and expensive), so
they should be kept short (see Table 2-1 on page 29).
However, the unit should NOT be installed in the battery
compartment due to the possible presence of explosive
hydrogen gas from the batteries.
Protected
from battery
acid and
gases
Never allow battery acid to drip on the inverter or its
wiring when filling the batteries or reading their specific
gravity. Do not mount the unit where it will be exposed to
gases produced by the batteries. These gases are corrosive
and prolonged exposure will damage the inverter.
Orientation To meet regulatory requirements, the TS400 must be
mounted on a flat horizontal surface with the front panel in
the upright position.
CAUTION
The TS400 Sine Wave Inverter must only be connected to
batteries with a nominal output voltage of 12 volts. The TS400
Sine Wave Inverter will not operate from a 6 volt battery and
will be damaged if connected to a 24 volt battery.