Xantrex Technology TS400 Marine Battery User Manual


 
Resetting After a Fault or Shutdown
975-0055-01-01 37
Resetting After a Fault or Shutdown
This section provides explanations and procedures for resetting the TS400
after a fault or shutdown.
If you are unable to resolve the problem after referring to Table 3-3, refer
to the Troubleshooting section on page 42.
Table 3-3
Resetting After a Fault or Shutdown
)DXOW 6WDWXV $FWLRQ
Shutdown The TS400 needs to be reset. Turn the On/Standby switch on either the
inverters front panel or the optional S400
Remote Switch to Standby ( ) and then to
On ( ).
Short Circuit If there is a short circuit, the
Supplemental Circuit
Protection button trips.
Remove the short circuit condition then press
the Supplemental Circuit Protection button.
Ground Fault When a fault condition is
detected, the Reset button on
the GFCI outlet trips and
power to the appliance is
interrupted.
Reset: To resume normal operation, determine
and correct the ground fault, then press the
Reset button.
Test: Press the Test button on the GFCI outlet
with the TS400 turned to On ( ). The Reset
button should trip. Press the Reset button to
reset the GFCI and continue with normal
operation. This test should be performed on a
monthly basis.
If the Reset button does not trip, the GFCI may
have failed. Contact your dealer to have a
qualified service person examine the TS400.
Overload The TS400 is designed to
provide 400 watts continuously
and 800 watts surge capability
for five seconds. If the
connected equipment draws
more than the rated power, the
TS400 will shut down and the
red Fault light illuminates.
Disconnect the equipment connected to the
inverter and then turn the On/Standby switch
on either the inverters front panel or the S400
Remote Switch to Standby ( ) and then to
On ( ).
See also Recharging Your Batteries on
page 35.