A SERVICE OF

logo

SKU 94143 For technical questions, please call 1-800-444-3353 PAGE 9
To Connect The Hydraulic Hoses:
RETURN LINE (40)
WIRING HARNESS (72)
PUMP INLET HOSE (8)
HIGH PRESSURE HOSE (10)
HYDRAULIC PUMP (52)
HYDRAULIC PUMP
MOUNT BRACKET (14)
OIL FILTER (70)
FIGURE C
1. Make sure there is enough slack in the Hydraulic Hoses and Wiring Harness (72)
to form a large, vertical loop. This will prevent the Hoses and wires from pulling
taut while the engine pivots during use and, therefore, help the Engine (15) pivot
to stay level. (See Figure C.)
Attach the High Pressure Hose (10) to the Hydraulic Pump (52). Attach the 2.
Pump Inlet Hose (8) to the Hydraulic Pump Mount Bracket (14). Then, attach the
Return Line (40) to the Oil Filter (70). (See Figure C.)
To Connect The Wiring Harness:
FIGURE D
ENGINE
GROUNDING
SCREW
BLUE (–)
GROUND WIRE
BLACK (+) ENGINE SNAP-IN RECEPTACLE
RED (+) WIRING HARNESS SNAP-IN PLUG
TO LOW OIL
SENSOR
1. Locate the BLUE Ground (–) Wire in the Wiring Harness. Then secure the BLUE
Ground Wire, using a bolt located on the Engine’s (15) Mount. (See Figure D.)
REV 07l