Sound Examiner Intrinsically Safe Models: user warnings, safety markings, and standard information
073-300 RevA
iii
Sound Examiner SE-401 and SE-402 Intrinsically Safe/Sécurité Intrinsèque Models: user warnings, safety markings, and standards information
WARNING: To prevent ignition of flammable or combustible atmospheres, there are no serviceable parts. Repair and battery
replacement must be done by authorized service personnel only.
Avertissement: Pour éviter l'inflammation d'atmosphères inflammables ou combustibles, il n'y a pas de pièces réparables.
Réparation et remplacement de la batterie doivent être effectués par le personnel de service autorisé.
WARNING: Substitution of components may impair intrinsic safety. Do not open.
Avertissement: La substitution de composants peut compromettre la Sécurité Intrinsèque.
WARNING: Contains built-in lithium polymer battery. Do not incinerate or dispose of in fire. Do not disassemble, alter, or re-
construct.
Avertissement: Contient la batterie intégrée au lithium polymère. Ne pas incinérer ou jeter au feu. Ne pas démonter, modifier
ou re-construire.
WARNING: To reduce the risk of explosion, recharge the battery outside of the hazardous locations.
Avertissement: Afin de prévenir l’inflammation d’atmosphères dangereuses, ne changer les batteries que dans des
emplacements désignés non dangereux.
Safety Standards
CE mark
0539 ,
SE-401 IS model and SE-402 IS model
UL 913, Ed.7, 2011-09-23: Standard for Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, III, Division 1,
Hazardous (Classified) Locations
CSA C22.2 No. 157-92, (R2013): Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations
EN 60079-0 (2009): Explosive atmospheres. Equipment. General requirements
EN 60079-11 (2012): Explosive atmospheres – Part 11: Equipment protection by intrinsic safety
EN 60079-26 (2007): Explosive atmospheres Part 26: : Equipment with equipment protection level (EPL) Ga
IEC 60079-0 Ed.5 (2007): Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60079-11 Ed. 6: (2012): Explosive atmospheres - Part 11: Equipment protection by intrinsic safety
IEC 60079-26 Ed. 2: (2009): Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
Safety Markings
Manufacturer
3M Company
Equipment/model
SE-401 Intrinsically Safe Class1/Type 1 model
SE-402 Intrinsically Safe Class 2/Type 2 model
Hazardous Locations Class
II 1 G Ex ia IIB T4 (DEMKO 13 ATEX 1210031X)
Ambient temperature range: -20ºC to +50ºC
Certificate number
IECEx UL 13.0006X, Class I, Division 1, Groups C and D;
Exi is defined as Intrinsically Safe and Sécruité Intrinsèque
Maximum charge input voltage
Um=5.5V
Maximum input current
Ii = 500ma
3M Authorized Service
Contact 3M
1060 Corporate Center Drive
Oconomowoc, WI 53066
Contact: 1-800-245-0779 or email: 3Mdetectionmail@mmm.com
or Internet: www.3m.com/detection
See User Manual for additional details.