20. Alerts
20-15
Alert number 871: ANCHORAGE AREA /5/12
Alert number 872: MARINE FARM/AQUACULTURE /5/12
Alert number 873: PSSA AREA /5/12
Alert number 874: ANCHOR WATCH /5/12
20.10.3 List of radar-related alerts
Alert number 100: RADOV NO HEADLINE 6/13
------------------------------------
NO HEADLINE AVAILABLE FOR RADAR
OVERLAY. CHECK CONNECTORS AND
CABLING FOR RADAR OVERLAY
Alert number 101: RADOV NO AZIMUTH 6/13
------------------------------------
NO AZIMUTH AVAILABLE FOR RADAR
OVERLAY. CHECK CONNECTORS AND
CABLING FOR RADAR OVERLAY
Alert number 102: RADOV NO TRIGGER 6/13
------------------------------------
NO TRIGGER AVAILABLE FOR RADAR
OVERLAY. CHECK CONNECTORS AND
CABLING FOR RADAR OVERLAY
Alert number 103: RADOV NO VIDEO /14
------------------------------------
NO VIDEO AVAILABLE FOR RADAR
OVERLAY. CHECK ADJUSTMENT OF GAIN ON
ON RADAR OVERLAY. CHECK CONNECTORS
AND CABLING FOR RADAR OVERLAY
Alert number 104: RADOV NO GYRO 6/13
------------------------------------
NO HEADING REFERENCE AVAILABLE FOR
RADAR PROCESSOR WHICH IS SOURCE FOR
RADAR OVERLAY. CHECK ARPA PROCESSOR
Alert number 106: LAN RADAR CONNECT FAILURE 5/12
------------------------------------
FAILURE TO ESTABLISH LAN CONNECTION
FOR ARPA FEATURES BETWEEN ECDIS
PROCESSOR AND ARPA PROCESSOR.
CHECK LAN CONNECTORS AND CABLES
POWER ON/OFF AND REINSTALL ECDIS SW.
Alert number 107: LAN RADAR DLL FAILURE 5/12
------------------------------------
FAILURE INSIDE ECDIS PROCESSOR
BETWEEN DLL INTERFACE SW AND ECDIS
SOFTWARE. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
Alert number 108: Watch Alarm 5/
------------------------------------
Alert number 109: RADOV NO ECHODATA 7/14
------------------------------------
FAILURE TO RECEIVE RADAR ECHO DATA
FROM ARPA PROCESSOR OVER LAN
CONNECTION CHECK LAN CONNECTORS AND
CABLES. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
Alert number 110: TT dangerous target 2/9
---------------------------------------