Commands
Advanced Operation
Advanced Operation
#use_discovery
Enables or disables discovery access mode. If this mode is disabled, then the
IP to 2 x RS-232 Converter will not be discoverable when using the Gefen Discovery Tool.
The default setting is enabled.
Syntax
#use_discovery param1
Parameters
param1 State
State Description
0
Discovery access disabled
1
Discovery access enabled
Example
#use_discovery 1
Discovery Access is set to Enabled
Related Commands