Graco 334945B Outboard Motor User Manual


 
Setup
ConnectConnect
Connect
PowerPower
Power
NOTE:NOTE:
NOTE:
All electrical wiring must be done by a
qualied electrician and comply with all local codes
and regulations.
1. Turn main power switch (MP) OFF.
2. Open electrical enclosure door.
NOTE:NOTE:
NOTE:
Terminal jumpers are located inside the
electrical enclosure door if equipped.
3. Install supplied terminal jumpers in the positions
shown in image for the power source used (H-30
and H-XP2 models only).
4. Route power cable through strain relief (EC) in
electrical enclosure.
5. Connect incoming power wires as shown in
image. Gently pull on all connections to verify
they are properly secured.
6. Verify all items are connected properly as shown
in image then close electrical enclosure door.
ti26342a_17D775
TableTable
Table
55
5
PowerPower
Power
CordCord
Cord
RequirementsRequirements
Requirements
ModelModel
Model
InputInput
Input
PowerPower
Power
CordCord
Cord
Specications*Specications*
Specications*
AWGAWG
AWG
(mm^2)(mm^2)
(mm^2)
200-240 VAC,
1 Phase
4 (21.2),
2 wire + ground
200-240 VAC,
3 Phase, DELTA
8 (8.4),
3 wire + ground
H-30, 10.2
kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
1 Phase
4 (21.2),
2 wire + ground
200-240 VAC,
3 Phase, DELTA
6 (13.3),
3 wire + ground
H-30, 15.3
kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
1 Phase
4 (21.2),
2 wire + ground
200-240 VAC,
3 Phase, DELTA
6 (13.3),
3 wire + ground
H-XP2,
15.3 kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
6 (13.3),
3 wire + ground
H-40, 15.3
kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
4 (21.2),
3 wire + ground
H-40, 20.4
kW
350-415 VAC,
3 Phase, WYE
6 (13.3),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
4 (21.2),
3 wire + ground
H-50, 20.4
kW
350-415 VAC,
3 Phase, WYE
6 (13.3),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
4 (21.2),
3 wire + ground
H-XP3,
20.4 kW
350-415 VAC,
3 Phase, WYE
6 (13.3),
4 wire + ground
*Values are for reference only. Refer to amperage
listed in Models table (see Models, page 9 ) for given
system and compare against latest version of local
electrical code to select proper power cord size.
NOTE:NOTE:
NOTE:
400 VAC systems are not designed to operate
from 480 VAC power source.
30334945B