If the system produces the T6DH Sensor Error Hose
alarm or the T6DT Sensor Error TCM alarm, use
manual hose heat mode until the hose RTD cable or
FTS temperature sensor can be repaired.
Do not use Manual Hose Mode for extended periods
of time. The system performs best when the hose has
a valid RTD signal and can operate in temperature
control mode. If a hose RTD breaks, the rst priority
is to x the RTD. Manual Hose Mode can help nish
a job while waiting for repair parts.
EnableEnable
Enable
ManualManual
Manual
HoseHose
Hose
ModeMode
Mode
1. Disconnect the hose RTD sensor from the TCM.
2. Enter Setup Mode and navigate to System
Screen 2.
3. Select Enable Manual Hose Mode.
NOTE:NOTE:
NOTE:
When manual hose mode is enabled, the
manual hose mode advisory EVCH-V will appear.
4. Enter Run Mode and navigate to the Target
screen. Use the up and down arrows to set the
desired hose current.
HoseHose
Hose
CurrentCurrent
Current
SettingsSettings
Settings
HoseHose
Hose
CurrentCurrent
Current
Default
20A
Maximum 37A