Graco 334945B Outboard Motor User Manual


 
Error Codes and Troubleshooting
JobJob
Job
LogLog
Log
The job log le name is 2–JOB.CSV and is stored
in the DATAxxxx folder.
The job log maintains a record of data points
based on the USB Log Frequency dened
in the Setup screens. The ADM stores the
last 237,000 data points for download. See
Setup - Advanced Screen 3 USB, page 35, for
information on setting the Download Depth and USB
Log Frequency.
Data point date
Data point time
A side temperature
B side temperature
Hose temperature
A side temperature setpoint
B side temperature setpoint
Hose temperature setpoint
Pressure A
Pressure B
A side inlet pressure (Elite only)
B side inlet pressure (Elite only)
A side inlet temperature (Elite only)
B side inlet temperature (Elite only)
Inlet pressure setpoint
System lifetime pump cycle counts
Usage Volume (manual)
Pressure, volume, and temperature units
Job name/number
DailyDaily
Daily
LogLog
Log
The daily log le name is 3–DAILY.CSV and is stored
in the DATAxxxx folder.
The daily log maintains a record of the total cycle
and volume sprayed on any day that the system is
powered up. The volume units will be the same units
that were used in the Job Log.
The following data is stored in this le:
Date that material was sprayed
Time unused column
Total pump cycle count for day
Total volume sprayed for day
SystemSystem
System
SoftwareSoftware
Software
LogLog
Log
The system software le name is 4–SYSTEM.CSV
and is stored in the DATAxxxx folder.
The system software log lists the following:
Date log was created
Time log was created
Component name
Software version loaded on the above component
BlackboxBlackbox
Blackbox
LogLog
Log
FileFile
File
The black box le name is 5–BLACKB.CSV and is
stored in the DATAxxxx folder.
The Blackbox log maintains a record of how the
system runs and the features that are used. This log
will help Graco troubleshoot system errors.
DiagnosticsDiagnostics
Diagnostics
LogLog
Log
FileFile
File
The diagnostics le name is 6–DIAGNO.CSV and is
stored in the DATAxxxx folder.
The Diagnostics log maintains a record of how the
system runs and the features that are used. This log
will help Graco troubleshoot system errors.
SystemSystem
System
CongurationConguration
Conguration
SettingsSettings
Settings
The system conguration settings le name is
SETTINGS.TXT and is stored in the DOWNLOAD
folder.
A system conguration settings le automatically
downloads each time a USB ash drive is inserted
into the ADM. Use this le to back up system
settings for future recovery or to easily replicate
settings across multiple systems. Refer to the
Upload Procedure, page 63 for instructions on how
to use this le.
62334945B