Spraying
SprayingSpraying
Spraying
TheFusionAPgunisshown.
1. Engage gun piston safety lock and close gun
uid inlet valves A and B.
FusionFusion
Fusion
ProblerProbler
Probler
2. Attach gun uid manifold. Connect gun air line.
Open air line valve.
3. Adjust the gun air pressure. Do not exceed 130
psi (0.2 MPa, 2 bar).
4. Set PRESSURE RELIEF/SPRAY valves (SA,
SB) to SPRAY .
SB
SA
GA
GB
5. Verify heat zones are on and temperatures are
on target, see Home screen, page 39.
6. Open uid inlet valve (FV) located at each pump
inlet.
7. Press to start motor and pumps.
8. Adjust pressure compensator knob to desired
uid stall pressure. Turn knob clockwise to
increase pressure and counter-clockwise to
decrease pressure. Use hydraulic pressure
gauge (HPG) to view hydraulic pressure. Once
desired uid stall pressure is set, lock the knob
in place by rotating lower portion clockwise until
tight.
Component A and B outlet pressures will be
higher than the hydraulic set pressure, depending
on the model. Component A and B (GA, GB)
pressure may be viewed on the pressure gauges
or the ADM.
334945B49