Advanced Display Module (ADM) Operation
HomeHome
Home
SystemSystem
System
OffOff
Off
This is the home screen when the system is off.
This screen displays actual temperatures, actual
pressures at the uid manifold, and number of cycles.
HomeHome
Home
SystemSystem
System
ActiveActive
Active
When the system is active, the home screen displays
actual temperature for heat zones, actual pressures
at the uid manifold, the number of cycles, along with
all associated control soft keys.
Use this screen to turn on heat zones, start the
proportioner, stop the proportioner, park the
component A pump, and clear cycles.
NOTE:NOTE:
NOTE:
Screen shown displays inlet sensor
temperatures and pressures. These will not be
shown on models without inlet sensors.
HomeHome
Home
SystemSystem
System
WithWith
With
ErrorError
Error
Active errors are shown in the status bar. The error
code, alarm bell, and description of the error will
scroll in the status bar.
1. Press to acknowledge the error.
2. See for corrective action.
TargetsTargets
Targets
Use this screen to dene the setpoints for the
A Component Temperature, B Component
Temperature, heated hose temperature, and
pressure.
MaximumMaximum
Maximum
AA
A
andand
and
BB
B
temperature:temperature:
temperature:
190°F (88°C)
MaximumMaximum
Maximum
heatedheated
heated
hosehose
hose
temperature:temperature:
temperature:
the lesser of
10°F (5°C) above the highest A or B temperature
setpoint or 180°F (82°C).
Note
If the remote display module kit is used,
these setpoints can be modied at the gun.
334945B39