Lucent Technologies 555-670-116 Marine Radio User Manual


 
MERLIN LEGEND Communications System Release 7.0
Pocket Reference
555-670-116
Issue 1
April 1999
111
Reference Documents
Maintenance Error Codes
Technical Addendum
Error
Code Description Action
0001 TIMEOUT COLD START:
System programming OK.
No action required; however, if
problem persists, troubleshoot
the processor.
0002 POWER UP WARM START:
System programming OK.
No action required; however, if
problem persists, troubleshoot
the processor.
0003 SOFTWARE COLD START:
System programming OK.
If problem persists, troubleshoot
the processor.
0004 SOFTWARE WARM START:
System programming OK.
If problem persists, troubleshoot
the processor.
0005 Reset - DIAGNOSTIC
SWITCH:
0006 INCOMPLETE COLD START:
System cold-started while
restart in progress.
If problem persists, troubleshoot
the processor.
0007 SANITY TIMEOUT RESET:
Faulty software, module, carrier,
or processor sanity timer.
Check module and/or
processor.
0008 MAX RESET COUNT
EXCEEDED:
System cold-started because of
too many warm starts.
If problem persists, troubleshoot
the processor.
0009 FRIGID START:
System restarted and initialized to
defaults; also logged after System
Erase.
If processor was removed while
in use, system may perform
frigid start because of loss of
system programming. Restore
system as described in
System
Programming and Maintenance
(SPM)
.
000A POWER UP COLD START:
RAM failure in processor; system
programming OK.
If problem persists, check
processor.
000B CARD
INSERTED/REMOVED:
None.
000C SLOT STREAM CNT
EXCEEDED:
Slot generated excessive
interrupts.
If problem persists, check
module.
000D FMWR NOT IN STANDBY
MODE:
Module firmware not in standby
mode.
If problem persists, check
module.
000E COMMAND BUFFER FULL:
If problem persists, check
processor and module.
000F
T
ASK RUNNING TOO LONG
None; if problem persists, check
processor.