Maintenance Error Codes
—Continued
Technical Addendum
Error
Code Description Action
0010 INVALID SLOT
INTERRUPT:
Cannot determine module
responsible for interrupt.
Check modules and replace if
necessary; if problem persists,
check processor.
0011 STACK OVERFLOW:
Processor problem.
Check processor.
0012 INVALID RESET FLAG:
Processor problem.
Check processor.
0013 DUART STREAMING INT:
Processor problem.
Check processor.
0014 PROCESSOR ERR
INTERRUPT:
Processor problem.
Check processor.
0015 MODULE MISMATCH:
Module inserted into wrong slot.
Change system
programming for proper module
or install proper module.
0016 POWER UP COLD START:
Module dual port ram failure;
system programming OK.
If problem persists, check
module for slot indicated.
0017 REAL TIME CLOCK FAULT:
Date and/or time incorrect or
unreadable.
If problem persists, replace
processor module.
0018 RTC COLD START:
This error is not displayed.
0019 RESET TIME & DATE:
System cold-starts because real-
time clock chip is not working
correctly.
If problem persists, replace
processor module.
0401 ABK CARD NOT INSERTED:
PCMCIA memory card for
translation is not inserted.
Insert a translation card or an
unformatted card.
0402 ABK INCORRECT CARD
TYPE:
PCMCIA memory card for non-
translation is inserted.
Remove current card and insert
a translation card or an
unformatted card.
0403 ABK CARD WRITE-
PROTECTED:
Translation card has write-
protected switch on.
Turn write-protection switch to
off. If problem persists, try
another card. If still not working,
replace processor module.
0404 ABK EXTENSION BUSY:
A station is in program,
administration, or maintenance
mode.
Wait until station changes
mode.