4.5.2 HTTPGET and ARP to setup Device IP Address
Use the iCONNECT software, which may be downloaded from our website, to
do these IP changes whenever possible.
Use ARP first to assign the mac address to a static IP address in computer arp table by
this command:
apr –s 192.168.1.200 00-03-34-00-00-06-b6
Then use the following command to assign new IP to the device:
Httpget –r –S "00000000" 192.168.1.200:1
where:
00000000” is admin. password. If the password is wrong, the unit will ignore the new IP.
If the new IP is taken, you will get the message " New IP is Assigned" after the httpget
command. The device will reset automatically.
192.168.1.200” is an example of an IP addresss. It is replaced with an IP address
suitable for your network
00-03-34-00-00-06-b6” is replaced with your iServer product MAC address.