Seiko Instruments LP-1020 Marine GPS System User Manual


 
Appendix-3
Basic specifications
Appendix
(2/2)
Items
Specifications/Function
LP-1020 LP-1020L
Noise
In operation : 61dB (A) or less (continuous sound)
In standby : 53dB (A) or less
Calorific value 4860 kJ or less
Power supply voltage
120VAC±10%
230VAC±10%
Frequency 50/60 Hz ± 1Hz
Power consumption
In operation : 1350 W or less
In standby : 45 W or less (in Power Save mode)
External dimensions
1154 (W) × 552 (D) × 1063 (H) mm
45.5 (W) × 21.7 (D) × 41.9 (H) inches
Weight 215 kg or less
Temperature/humidity
range in use of plotter
15 to 35˚ C/20 to 80%RH (no dew condensing)
Humidity should be 48% or less when temperature is 35˚ C, or
temperature should be 28˚ C or less when humidity is 80%RH.
Temperature/humidity
range in nonuse of plotter
-5 to 40˚ C/10 to 90%RH (no dew condensing)
Installation space
2054 (W) × 1662 (D) × 1500 (H) mm
80.9 (W) × 65.5 (D) × 59.1 (H) inches
Maintenance space
2554 (W) × 2052 (D) × 2000 (H) mm
100.6 (W) × 80.8 (D) × 78.8 (H) inches