Taylor h-71 h-84 Marine Heating System User Manual


 
20
Models H71 & H84Important: To the Operator
The SER VINGS COUNTER screen indicates the
number of times the draw switch has closed (number
of draws) since the last brush cleaning or since the last
serving counter reset. A maximum of 32,767 draws
can be recorded; an additional draw will cause the
counter to restart at zero. Pressing the MENU key/SEL
will return the display to the Operator Menu.
H71 Screen:
SERVINGS COUNTER
DRAWS
12
SEL
H84 Screen:
SERVINGS COUNTER
LEFT RIGHT
12 15
SEL
Draws are counted during the AUTO mode of
operation only.
Screen “G” is HEAT CYCLE DATA. The information
from the p revious heat treatment cycles can be
obtained through this screen. The most recent heat
treatment cycle data will be shown first; p ress the plus
key to scroll through the remaining heat cycle displays.
If a heat treatment cycle failure should occur, a 2
character message will appear on the second line of
the screen. Press the SEL key once to return to the
OPERATOR MENU.
Listed below are the variable messages which could
appear:
HT Failure in the heating phase.
CL Failure in the cooling phase.
TT F ailure in meeting total heat treatment cycle
time requirement.
MO Mix out condition.
OP Operator interruption.
PF Power failure. (If a power failure occurs, but
the heat treatment cycle does not fail, an
asterisk (*) will appear on the third line of the
display.)
BO Beater overload.
HO High pressure cut-out.
TH Failed thermistor probe.
PS Power switch placed in the OFF position.
ML Mix Low Condition.
14 14 Day Timeout Occurred.
RC Heat Cycle Record Cleared.
11/07 02:00 05:09
HEAT OVER COOL XX
01:09 00:45 01:14
TEMP AT END 38.5 1