Taylor h-71 h-84 Marine Heating System User Manual


 
21
Models H71 & H84 Important: To the Operator
Pressing the left arrow key on any HEAT CYCLE DATA
screen will cause the extended data screen to be
displayed. This screen shows the hopper, barrel, and
glycol temperatures, and the amount of time the
freezer spent in the phases of the heat cycle when the
heat cycle completed, or was terminated.
H71 Screen:
HOPPER BARREL GLYCOL
151.0 134.5 178.0
PHASE TIME: 1:20 1
H84 Screen:
HOPPER BARREL GLYCOL
151.0 134.5 98.1
153.0 136.0
PHASE TIME: 1:20 1
Screen “H” is the LOCKOUT HISTORY. This screen
displays a history of the last 40 hard locks, soft locks,
and brush clean dates. Page numbers are indicated in
the upper right hand corner. Page 1 always contains
the most recent failure. Press the +++ key to cycle
through the pages.
The second line of the screen displays the date and
time a failure occurs. The third line indicates the
reason for a failure, or will indicate a successful brush
cleaning has occurred. Some failures occur for
multiple reasons. When this occurs, a page will be
generated for each reason. Press the SEL key once to
return to the Operator Menu, or twice to return to the
Main Screen.
LOCKOUT HISTORY 1
06/11/01 02:08
SOFTLOCK ABORT
+ + + -- -- -- S E L
Screen “I” is the SERVICE MENU. This screen can
only be accessed b y a service technician.
Screen “J” is the STANDBY MODE. To place the
freezer in the STANDBY mode, move the cursor under
the word “yes”. Press the SEL key to execute the
command. Pressing the SEL key again will return you
to the main screen. To exit the STANDBY mode and
place the unit in AUTO, press the AUTO key once.
Pressing the AUT O key again will place the unit in the
OFF mode.
H71 Screen:
STANDBY MODE
STANDBY YES NO
-- -- --
<--- ---> SEL
H84 Screen:
STANDBY MODE
LEFT YES NO
-- -- --
<--- ---> SEL
STANDBY MODE
RIGHT YES NO
-- -- --
<--- ---> SEL