Taylor h-71 h-84 Marine Heating System User Manual


 
31
Models H71 & H84 Operating Procedures
Step 1
When the heating cycle is complete, the normal dis-
play will appear, showing the machine in the STAND-
BY mode. Prepare a small amount of an approved 100
PPM sanitizing solution (example: Kay-5r). USE
W ARM WATER AND FOLLOW THE MANUF ACTUR-
ER’S SPECIFICATIONS.
Sanitize the design caps, air orifices, front drip tray,
and the splash shield in this solution.
Step 2
Return to the freezer with a small amount of sanitizing
solution. Dip the end brush into the sanitizing solution
and brush clean the door spout and bottom of the draw
valve.
Note: To assure sanitary conditions are maintained,
brush clean each item for a total of 60 seconds,
repeatedly dipping the brush in sanitizing solution.
Step 3
Rinse a single service towel i n sanitizing solution and
wipe down the freezer door and area around the
bottom of the freezer door.
Replace the design caps, air orifices, front drip tray
and the splash shield.
MAKE SURE Y OUR HANDS ARE SANITIZED
BEFORE PERFORMING THIS NEXT STEP!
Step 4
Lift the hopper cover and turn the inner air tube of the
assembled air tubes so the pin rests at the bottom of
the notch of the outer air tube.
12155
Figure 32
Step 5
Press the A UTO key to resume normal operation.
When the unit cycles off, product is ready to serve.
Manual Brush Cleaning
THIS PROCEDURE MUST BE DONE EVERY 14
DAYS!
ALWAYS FOLLOW LOCAL HEALTH CODES.
To disassemble your unit, the following items will be
needed:
S T wo cleaning pails
S Necessary brushes (provided with freezer)
S Cleaning solution
S Single service towels
Draining Product From The Freezing
Cylinder
Step 1
Press the AUTO key, cancelling compressor and
beater motor operation.
Step 2
Remove the hopper cover, agitator, and assembled air
tube from the mix hopper. Take these parts to the sink
for cleaning.
Step 3
With a pail under the door spout, p ress the WASH key.
Open the draw valve and drain the remaining product
from the freezing cylinder and mix hopper.
Step 4
When the flow of p roduct stops, press the WASH key,
cancelling the wash cycle and close the draw valve.
Discard this product.
Repeat Steps 1 through 4 for the other side of the
freezer on the Model H84.